ePED® service interface USB

Article number: 1386D00------00

Product description

Single module in Hi-O bus technology with optimized operating concept. To control locking/unlocking, temporary unlocking, alarm acknowledgement through a potencial-free contact such as card reader, door code systems or others. Or to conventionally control through key switch, tested in compliace with EltVTR.

Overview of Advantages

  • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
  • Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
  • Emergency button sign (arrow pointing downwards)
  • Acoustic signal and tampering contact
  • Adjustable time period for delayed permanent release, temporary release, pre-alarm, alarm interval, guidance signal
  • Monitoring of time door is open in the case of temporary unlocking
  • With two inputs featuring adjustable parameters for: control via an external operating element or; temporary release via AC system or; emergency locking via fire alarm system or; unlocking via switching timer.
  • With a relay output featuring adjustable parameters for: door locked/unlocked, door open/closed, common alarm, individual alarm or activation of electric strike/ motorised lock/ revolving door drive/ arrestor system.
  • System connector for setting parameters with ePED® service interface and software for MS Windows
  • Connections: SYSCON-4: Hi-O bus; SYSCON-5: operating unit, screw/ plug-in terminals
Technical data