Control terminal

Product description

To control electric locking systems in doors along escape routes; certified.

Escape door control module

  • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
  • Integrated door status indicator (green / red / yellow) signalling unlocked / locked / alarm status
  • Sign emergency button
  • alarm signal and tampering contact;
  • Key switch to control door
  • With Euro profile half cylinder, including 3 keys
  • Adjustable time intervals for temporary release, pre-alarm, alarm interval
  • Monitoring of time door is open during temporary release.
  • TS bus interface for parallel operation of visualisation software, panel and OPC server
  • Connections: screw terminals
Technical data
Output voltage12 or 24 V DC
Max. output currentMax. 0.64 A (depending on external power supply)
*Nicht Übersetzt: Eigenstromaufnahme0.2 A at 12 V / 0.15 A at 24 V
ControlYes, integrated
Power supplyNot integrated, external power supply required
Configured centrally using FT ManagerNo
Stand-alone operation with I/O moduleNo
Stand-alone operation (offline)Yes
Emergency switchYes
Control elementKey switch with Euro profile cylinder; cam position 8 x 45°; 30.5 mm long
Setting of times and functionsVia DIP switches
Operating temperature range0 °C to +40 °C
Class of protectionIP 20
Dimension(HxWxD) 249x92x98 mm
InputsE1: temporary release; E2: fire alarm system; E3: timer
Key switch on opposite side to direction of escapeYes
Escape door terminal with bi-directional escape routeNo
Variants that can be ordered
Order number
Description
1340-20-----E9012 V; surface-mounted; signal green RAL 6032
1340-20-----F9024 V; surface-mounted; signal green RAL 6032
1340-14-----E9012 V DC; offline; without power unit; surface mount
1340-14-----F9024 V DC; offline; without power unit; surface mount