Surface-mounted escape door terminal with blind cover
Product description
To control electric locking systems in doors along escape routes; certified.
Escape door control module
- Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
- Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
- Emergency button sign (arrow pointing downwards)
- Multi-tone signal and tampering contact
- Adjustable time period for max. continuous release, delay in continuous release, temporary unlocking, pre-alarm, alarm interval, guidance signal
- Monitoring of time door is open in the case of temporary unlocking
- With an input featuring adjustable parameters for:
- Control of locking and unlocking, temporary unlocking, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units, or
- Temporary release using an access control system, or
- Emergency release via fire alarm system, or
- Priority locking via burglar alarm system, or
- Unlocking via timer and many other systems
- With a relay output featuring adjustable parameters for:
- Door locked/unlocked, or
- Door open/closed, or
- Collective alarm, or
- Individual alarm, or
- Activation of electric strike/motorised lock/door automatics/arrestor system
- TS bus interface for parameterisation using software (FT Manager) and networks for parallel operation of visual display software, panel and OPC server
- Connections:
- SYSCON-4: power supply
Key switch module
- For locking/unlocking, temporary unlocking, alarm resetting
- Sabotage switch
- With Euro profile half cylinder, including 3 keys
- Cover which matches the corresponding switch fitting
Scope of delivery
- 1 escape door control module
- 1 key switch module
- 1 frame
- 1 operating manual
- 1 unit blind cover
Note
- Gira Profil 55, aluminium finish
Output voltage | Depends on input voltage |
Input voltage | 12 V DC -15% to 24 V DC +15% controlled direct-current (DC) voltage (SELV) |
Total power consumption | 0.1A at 24V |
Max. output current | Max. 1 A (depending on external power supply) |
Area of application | For indoor use, without condensation |
TS-Bus interface | Yes |
Control | Mains receiver necessary |
Key switch on opposite side to direction of escape | Yes (without display) |
Setting of times and functions | Via key switch, via FT Manager (together with bus controller) |
Control element | Key switch with Euro profile cylinder; cam position 8 x 45°; 30.5 mm long |
Dimension | In triple, surface-mounted housing, Gira profile 55 range |
Operating temperature range | -5 °C to +40 °C |
Inputs | 1x; parametrisable; low-active |
Class of protection | IP 30 |
Power supply | Can be integrated, not included in delivery |
Outputs | 1x; 30 V / 1 A switchover contact; adjustable parameters |
Escape door terminal with bi-directional escape route | No |
Stand-alone operation with I/O module | Yes |
Stand-alone operation (offline) | Yes |
Emergency switch | Yes |
Connection | Yes |