Electric strike 118F.20-----A71
Product description
Model with monitoring contact as potential-free changeover contact, actuated by the latch bolt.
Overview of Advantages
- Radius keep, FaFix®, adjustable by 3 mm
- Voltage range
- Compatible with DIN 18250 mortise locks
- Compatible with ProFix® 1 striking plates
- Optimal outlet slopes for gentle interaction with the latch bolt
- Symmetrical design. DIN left/right as well as horizontal applicable
- Bipolar diode
Scope of delivery
- 1 piece electric strike
DIN-direction | Universal |
Adjustable keeper (FF, FaFix®) | Yes |
Monitoring contact (RR) | Yes |
Fail-locked | Yes |
Bi-directional diode | Yes |
Continuous duty | 11-13 V DC |
Rated resistance | 43 Ohm |
Switching capacity - monitoring contact | 24 V / 1 A |
Current consumption 12 V AC | 250 mA |
Current consumption 12 V DC | 280 mA |
Current consumption 24 V AC | 500 mA |
Current consumption 24 V DC | 560 mA |
current consumption | 250 mA |
Current consumption AC 12 V | 250 mA |
Current consumption DC (stabilised) | 280 mA |
Current consumption DC (stabilized) 12 V | 280 mA |
Height | 75 mm |
Width | 25 mm |
Depth | 25,5 mm |
Break-in resistance | 9000 N |
FaFix® adjustment range | 3 mm |
Latch bolt engaging depth | 6 mm |
Operating temperature range | -15 °C to +40 °C |
Load cycles for in-plant test | 250000 |
Installation position | Vertical and horizontal |
Suitable for fire doors | Yes |
Certified in compliance with | EN 14846:2008 |
Max. latch preload DC (stabilised) 12 V | 50 N |
Max. latch preload DC (stabilised) | 50 N |
Max. latch preload AC | 200 N |
VdS-approval | Z114003 |