Switch cylinder eCLIQ N512

30 mm Diameter , laterally flattened to 22 mm -without key-

Product description

  • Available as electronical version (V=)
  • Switch cylinder with one key withdrawal position at 0° and one scanning position at 60°
  • Brass cylinder housing components
  • Standard finish, satin nickel-plated (OF=MV)
  • Maintenance-free for up to 200,000 cycles
  • Dust and rain cover available (SUR=1) IP55
  • Optionally available for use in potentially-explosive atmospheres in Zone 1 (ATEX=II 2G EX IB IIB T4 Gb)
  • Optionally available for permanent activation of the switch VAR=RASTUNG without key withdrawal on the scanning position
  • Two microswitches F4T 7-GP UL (Burgess) (VAC 250 V/ resistive load 5A, VAC 250 V/ inductive load 0.5 A)
  • Key rotation 60°
  • A rotation actuates a switch device (e.g. underground car parks, etc.).
  • Splash-proof IP54
  • Fixing with M30x1.5 housing nut

Scope of delivery

  • 1 switch cylinder
  • 1 housing nut M30 x 1.5 x 4
Variants that can be ordered
Article numberOF=AUS=V=
N512 MV 1E
Special equipment

Explosion protection

ATEX=DescriptionInfo
II 2G Ex ib IIB T4 GbLocking cylinders for Zone 1 hazardous areasper cylinder

Version

V2=AUS3=DescriptionInfo
ONLINECylinder with function "Online Open", frontal marking with symbol "@"per cylinder
SEQUENCECylinder with function "two-man rule", frontal marking with symbol "&"per cylinder
OHNE AUDITCylinder without events list, frontal marking with symbol "§"per cylinder

Special finish

OF=SurfaceArea of applicationInfo
MVBrass, nickel-coatedFor profile and locking lever cylindersper cylinder
MGBrass, satin brushedFor profile and locking lever cylindersper cylinder
MPPolished brassFor profile and locking lever cylindersper cylinder
MCBrass, satin chrome-platedFor profile and locking lever cylindersper cylinder

Dust and rain protection

SUR=Area of applicationInfo
1For special cylindersper cylinder

Variant

VAR=DescriptionArea of applicationInfo
RASTUNGPermanent activation of the switch without key withdrawal on the scanning positionFor switch cylinder .512per cylinder